DARATAIN SE
Slump maintaining admixture
Product Description
Daratain SE is a revolutionary advancement in time-activated, polycarboxylate-based technology. This specifically engineered technology enables slumps / flows to be maintained when used in conjunction with all GCP Mira & ADVA admixtures. Daratain SE is formulated to comply with the requirements of AS 1478 Type SN. Daratain SE does not contain chloride as a functional ingredient. Daratain SE is manufactured under closely controlled conditions and formulated for use as received. One litre weighs approximately 1.06kg ± 0.02kg.
Uses
Daratain SE is specifically intended for use where slump/flow maintenance is required with minimal influence on setting times. Daratain SE produces concrete with consistent slump properties while providing the degree of workability necessary to provide easy placement and consolidation.
Conventional high range water reducers may not provide sufficient slump life for applications with unpredictable or long transportation and placement times. As a result, concrete may be re-tempered with water at a job site to achieve desired workability. The addition of Daratain SE used in conjunction with Type HWR Superplasticiser eliminates the need for re-tempering at job sites to achieved the desired workability.
Product Advantages
- Flexible degree of slump retention through adaptable dosing
- Increases slump life with minimal impact on set times
- Better control of operational costs by adjusting the slump life retention on an "as needed" basis during the initial dosage adjustment
- Eliminates the need for re-tempering with water at the job site
- Improves workability at job sites resulting in ease of placement
- Offers some water reduction
Compatibility with Other Admixtures and Batch Sequencing
Daratain SE is compatible with all water reducers, midrange water reducers and high range water reducers from GCP Applied Technologies, as long as they are added separately to the concrete mix. In general, it is recommended that Daratain SE be added to the concrete mix near the end of the batch sequence for optimum performance. Different sequencing may be used if local testing shows better performance.
Pretesting of the concrete mix should be performed before use and as conditions and materials change in order to assure compatibility with other admixtures, and to optimise dosage rates, addition times in the batch sequencing and concrete performance.
Dispensing Equipment
Please contact your local GCP representative for further information regarding the dispensing equipment for this product.
Addition Rates
Addition rates of Daratain SE can vary with the type of application and the desired slump specifications but will range from 50 to 500mL / 100kg of total cementitious as an extended slump life admixture. In most instances, the addition of 100 to 200mL / 100kg of total cementitious will be sufficient. At higher dosage rates, some water may have to be removed from the mix to maintain plastic concrete cohesion. GCP strongly recommends pretrial testing the concrete (lab and field) with Daratain SE before production use to optimise dosage rates due to concrete materials, ambient conditions and project requirements that change over time. Please consult your local GCP representative for more information and assistance.
Packaging and Handling
Daratain SE is available in bulk, delivered by metered trucks, in 1,000L disposable totes and 205L drums.
Daratain SE should be stored at temperatures above 0ºC and below 50ºC for proper dispensing and use. It will begin to freeze at 0ºC but will return to full strength after thawing and thorough agitation.
Material Safety Data Sheet (MSDS) is available on request.
Health and Safety
Please refer to Daratain SE MSDS or consult GCP Applied Technologies.
gcpat.com.au | Australia customer service: 1800 855 525
We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right.
GCP is a trademark, which may be registered in the United States and/or other countries, of GCP Applied Technologies, Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark ownership or status.
© Copyright 2024 GCP Applied Technologies, Inc. All rights reserved.
GCP Applied Technologies Inc., 2325 Lakeview Parkway, Alpharetta, GA 30009, USA GCP Australia Pty. Ltd., 14 Colebard Street West, Archerfield, Brisbane, Queensland 4108, Australia This document is only current as of the last updated date stated below and is valid only for use in Australia. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com.au. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service.
Last Updated: 2024-09-20
https://gcpat.com.au/en-gb/solutions/products/daratain-se